Mössbauer Spectroscopy
- Mössbauer spectroscopy (MS) is based on resonant emission and absorption of gamma rays
- MS is used to study various sample types (including both nano-sized objects and bulk materials) with specific nuclei
- MS gives both physical and chemical structure information
- MS is extremely precise, non-destructive analysis technique
- MS is capable to analyze samples with low-concentration of specific nuclei
- MS is limited on solid samples only (frozen liquids are also suitable)
- Radioactive source is required for MS

Complete Mössbauer spectroscopy solution
Transmission Mössbauer Spectrometer typical experimental setups are described below.
We are capable of experimental setup customization like:Low-temperature measurements
High-temperature measurements
Conversion Electron/X-Ray measurements (in combination with transmission spectrometer a simultaneous conversion and transmission measurementis possible)
And more...
We are capable of experimental setup customization like:
MS96 – The 3rd Generation Hardware Based Mössbauer Spectrometer
- This represents third-in-row design of Mössbauer spectrometer
- Complete signal processing and spectra accumulation is provided by specialized hardware units
- Designed as stand-alone device, with all necessary components integrated in one body (including personal computer), or as standard NIM module.
- Stand-alone version includes:
- Intelligent Nuclear Detector Mark II
- Neodymium Velocity Transducer with built-in analog velocity feed-backPID controller
- Spectrometric bench
- Stand-Alone Main Unit
- NIM version includes:
- Intelligent Nuclear Detector Mark II
- Neodymium velocity transducer with built-in analog velocity feed-back PID controller
- Spectrometric bench
- NIM Main Unit
MS96 – VI: Virtual Instrument Based Mössbauer Spectrometer
- Complete signal processing is provided by software application on personal computer equipped with specialized digitizers and signal generators
- Virtual Instrument version includes:
- Intelligent Nuclear Detector Mark I
- Neodymium velocity transducer with built-in analog velocity feed-backPID controller
- Spectrometric bench
- National Instruments fast digitizer
- National Instruments generator
- Personal computer (on request)

Individual Mössbauer spectroscopy components

MS96 – The 3rd Generation Stand-Alone Main Unit
- Complete Mössbauer spectrometer main unit solution, including:
- Spectrum registration unit, velocity generator unit, input signal processing unit, personal computer and power supply
MS96 – The 3rd Generation NIM Main Unit
- Mössbauer spectrometer main unit in standard NIM housing (2 unit), including:
- Spectrum registration unit, velocity generator unit, input signal processing unit
- Controlled by personal computer (has to be connected externally via standard USB interface)
MS96 – The 3rd Generation NIM Universal Spectrum Registration Unit
- Separated spectrum registration unit in standard NIM housing (1 unit)
- Spectrum registration unit is compatible with all known Mössbauer spectrometers
- Controlled by personal computer (has to be connected externally via standard USB interface)

Intelligent Nuclear Detector Mark I. and Mark II.
- Complete detection unit for transmission measurements equipped with signal processing units
- Transmission measurement provides information about sample’s volume
- Based on scintillation detector, with electronically controllable both amplification and high-voltage level (I2C or USB Interface)
- Internal function is controlled and all operating parameters are stored by a microcontroller
- In a single small-sized body Mark I. includes:
- Scintillation detector
- High-Voltage power supply
- Preamplifier and Amplifier
- Internal temperature monitor
- Mark II. additionally includes Single-Channel Analyzer unit and two signal outputs (analog and logic)

Neodymium Velocity Transducer
- Electrodynamic velocity transducer based on neodymium magnets
- Includes integrated velocity feedback PID controller

Electronically Controllable High-Voltage Power Supply and Signal Amplifier
- Standard NIM or individual housing, standard SHV connection
- Function is controlled using USB interface

Conversion Electron/X-Ray Detector
- Conversion Electron/X-Ray measurement provides information about sample’s surface
- Gas flow detector for conversion measurements is designed to combine it with transmission detector (thus two spectra can be obtained simultaneously)
- Multi-wire anode is used in this detector

Low-temperature Equipment
- Liquid nitrogen bath cryostat with vacuum experimental cell usable for frozen liquid samples
- Conversion Electron/X-Ray detector for low tremperature measurements
- Helium cryostat on request
We offer complete Mössbauer spectroscopy instrumental and scientific support.
Detailed information and all parameters at www.mossbauer-spectrometers.com
Any additional information on request: rcptm.services@upol.cz
Detailed information and all parameters at www.mossbauer-spectrometers.com
Any additional information on request: rcptm.services@upol.cz